Definitions marked with a code note are general information only. Local ordinances, the Illinois Plumbing Code (77 Ill. Adm. Code 890), and the Illinois Plumbing License Law (225 ILCS 320) govern what is required in your jurisdiction. When in doubt, contact your local building department or a licensed plumber.

157 terms

A

ABS

Pipe & Fittings

Acrylonitrile butadiene styrene — a rigid black plastic pipe used for drain, waste, and vent lines. It was common in homes built from the 1960s through the 1980s. ABS is glued with a one-step solvent cement (no primer required, unlike PVC). It is not interchangeable with PVC without an approved transition fitting.

You'll hear this when a plumber identifies the black drain pipes in an older home, or when you're buying fittings and need to match the existing pipe material.

Aerator

Fixtures & Parts

The small screen screwed onto the tip of a faucet spout. It mixes air into the water stream to reduce splashing and lower water use. Aerators collect mineral deposits over time and are one of the first things to check when a faucet has low pressure.

You'll hear this when a plumber or guide tells you to unscrew the tip of your faucet to clean or replace the screen.

Air admittance valve (AAV)

Drains / Waste / Vent Code note

An air admittance valve is a one-way valve on a drain that opens to let room air in when a fixture drains, then closes so sewer gas cannot come out. It can help a fixture that is hard to vent to the roof. It does not vent the whole house, and it does not fix a blocked roof vent. A stuck AAV makes the fixture gurgle or smell.

You'll hear this when someone suggests a studor valve under a sink instead of a vent through the roof.

AAV use under the Illinois Plumbing Code is limited, and many cities prohibit them or allow them only on remodels. An AAV that the state code might allow can still fail a local inspection. Ask the building department before you install one.

Air gap

Codes & Safety Code note

An air gap is a physical open space between the end of a water outlet or a drain hose and the flood rim of a sink or standpipe. It is the simplest backflow protection because water cannot jump the gap backward. Dishwashers, reverse-osmosis drains, and softener drains are common places you need one. A hose stuffed into a standpipe, below the rim, is not an air gap.

You'll hear this when a dishwasher drain or an RO tube has to stay above the sink rim.

The Illinois Plumbing Code sets minimum air gaps. For an indirect waste, the gap is at least twice the pipe diameter and never less than one inch, and some fixtures require more. See the code rather than a guess.

Angle stop

Fixtures & Parts

A shutoff valve whose inlet and outlet are at a 90-degree angle to each other — the most common type found under sinks and toilets. The supply line comes out of the wall horizontally, and the valve turns the flow 90 degrees up toward the fixture. Also called an angle valve or supply stop.

You'll hear this when a plumber says to turn off the angle stop before replacing a faucet or toilet supply line.

Anode rod

Water Heaters

A long metal rod — usually magnesium or aluminum — suspended inside a tank water heater. It attracts corrosive minerals in the water, sacrificing itself so the steel tank doesn't rust. Replacing it every few years is the single best way to extend a water heater's life.

You'll hear this when a plumber recommends routine water heater maintenance, or when you notice a rotten-egg smell from your hot water (a sign the rod has been depleted).

B

Backflow

Codes & Safety Code note

The unwanted reversal of water flow in a plumbing system — for example, contaminated water flowing backward into the clean supply. Backflow preventers are required by code on irrigation systems and some appliances. This definition is general information; Illinois Plumbing Code and local amendments govern specific requirements.

You'll hear this when a plumber inspects an irrigation system, or when your municipality requires a backflow test on your connection.

Backflow preventer

Codes & Safety Code note

A backflow preventer is a device that keeps used water, chemicals, or boiler water from being sucked or pushed back into the potable supply. The right device depends on the hazard. A hose bibb may need a vacuum breaker. A lawn sprinkler or a boiler may need a heavier assembly. Installing the wrong one, or none, is how a house contaminates a water main.

You'll hear this when a plumber or the water department talks about protecting the potable water.

77 Ill. Adm. Code 890.1130 covers protection of potable water. The device has to match the hazard, and many assemblies have to be tested by a certified cross-connection control device inspector.

Ball valve

Pipe & Fittings

A ball valve shuts off water with a quarter turn of a lever. Handle in line with the pipe means open. Handle across the pipe means closed. It is the valve you want on a main shutoff because you can tell the position from across the room.

You'll hear this when someone says the main is a ball valve, not a gate valve.

Ballcock

Fixtures & Parts

An older style of toilet fill valve that uses a floating ball on an arm to sense the water level in the tank. When the tank empties during a flush, the ball drops and opens the valve; as the tank refills, the ball rises and shuts the valve off. Most modern toilets use a float-cup fill valve instead, but ballcocks are still found in older toilets and are still sold as replacement parts.

You'll hear this when diagnosing a running toilet in an older home, or when a hardware store associate asks what type of fill valve you have.

Basket strainer

Fixtures & Parts

The drain fitting that sits in the bottom of a kitchen sink. It has a removable basket that catches food debris, and a stopper function that lets you fill the sink with water. The strainer body threads into the drain opening from below and is sealed with plumber's putty or a rubber gasket. Leaks at the basket strainer are a common source of under-sink drips.

You'll hear this when a plumber diagnoses a leak under a kitchen sink, or when you're replacing a kitchen sink and need to install the drain.

Belly in a line

Drains / Waste / Vent

A belly is a sag in a drain where the pipe dips and then rises again. Water and solids sit in the low spot. Snaking it clears the symptom until the belly fills back up. The repair is to rehang or replace that section so the slope is continuous. You find a belly with a camera, not by guessing.

You'll hear this when a line clogs in the same spot over and over and the camera shows standing water.

Braided supply line

Water Supply & Quality

A braided supply line is the flexible hose, usually stainless braid over rubber, that connects an angle stop to a faucet or toilet. It is always under pressure. When the braid bubbles, rusts at the crimp, or weeps along its length, replace the whole line. Do not try to patch it.

You'll hear this when a cabinet is wet and the drip is on the hose, not the drain.

Branch drain

Drains / Waste / Vent

A branch drain is the pipe that serves a room or a group of fixtures and then joins a larger drain. A slow tub and a slow sink in the same bathroom, with the rest of the house fine, usually means the clog is in their branch.

You'll hear this when one bathroom is slow and the kitchen is not.

Brine tank

Water Supply & Quality

The brine tank is the softener's salt tank. Salt dissolved in water makes the brine that regenerates the resin. A salt bridge is a hard crust with an empty space under it, so the tank looks full and the softener is not actually salting. Break a bridge carefully. Do not pour bags of salt into a tank that is already full of water and not using it.

You'll hear this when a softener stopped softening and the salt looks solid.

BTU

Water Heaters

A BTU is a British thermal unit, a measure of heat. Water heaters are rated by how many BTUs per hour they can put in. A bigger number is not always better. The heater, the gas line, and the vent have to match. Too many BTUs on a gas line that is too small gives you a heater that will not stay lit.

You'll hear this when someone compares heater sizes by BTU instead of by gallon.

Building drain

Drains / Waste / Vent Code note

The building drain is the lowest horizontal drain inside the house. It picks up the branches and carries waste to the point where the pipe becomes the building sewer, a short distance outside the building. A backup that shows up at the lowest floor drain is often in this pipe or just beyond it.

You'll hear this when a plumber says the clog is in the building drain, not in a single bathroom.

The Illinois Plumbing Code defines the building drain and how it must be sized, sloped, and cleaned out. Your city can add rules. This is general information, not a design.

C

Cartridge

Fixtures & Parts

A self-contained valve mechanism inside a single-handle or two-handle faucet. Turning the handle moves the cartridge to control water flow and temperature. When a faucet drips or is hard to turn, the cartridge is usually the part that needs replacing.

You'll hear this when a plumber or guide tells you to pull out the cartridge to fix a dripping faucet.

Cast iron pipe

Pipe & Fittings

Heavy, durable iron pipe used for drain, waste, and vent lines in homes built before the 1970s. It is extremely quiet compared to PVC and can last 50-100 years, but it is heavy, difficult to cut, and can corrode from the inside over time. Repairs typically use no-hub (Fernco-style) couplings to join cast iron to modern PVC or ABS.

You'll hear this when a plumber inspects an older home's drain system, or when you notice the difference in noise between old and new drain pipes.

Cleanout

Drains / Waste / Vent

A capped access point in a drain or sewer line that lets a plumber insert a snake or camera to clear blockages or inspect the pipe. You'll often find one near the base of a toilet, under a sink, or outside the house near the foundation.

You'll hear this when a plumber needs access to the drain line to clear a clog or run a camera.

Closet auger

Fixtures & Parts

A closet auger is a short toilet snake with a bent housing that lets you feed the cable through the bowl and into the toilet's built-in trap. It is the tool for a clog a plunger did not move. It is not the tool for a main sewer line.

You'll hear this when a plunger failed and the clog is still in the toilet, not in the yard.

Closet bolt

Fixtures & Parts

Closet bolts are the two bolts that hold a toilet down to the closet flange. They stick up through the base. The caps over the nuts are cosmetic. If the toilet rocks, tightening these a little may help, but overtightening cracks the china, and a rock often means the wax ring or the flange is already in trouble.

You'll hear this when a toilet wobbles and someone checks the closet bolts before they pull the toilet.

Closet flange

Fixtures & Parts

The fitting that connects the toilet to the drain pipe in the floor. It has a flat ring (the flange) that the toilet bolts to, and a hub that fits into the drain pipe below. The wax ring seals between the toilet horn and the flange. A cracked or corroded flange is a common cause of toilet leaks at the base and floor damage.

You'll hear this when a plumber removes a toilet and finds the flange is broken, or when you're replacing a toilet and need to check the condition of the floor connection.

Compression fitting

Pipe & Fittings

A type of pipe connection that uses a threaded nut and a small brass ring (ferrule) to create a watertight seal without soldering. Common on supply lines under sinks and on shutoff valves. Tighten by hand, then snug with a wrench — overtightening can crack the ferrule.

You'll hear this when replacing a shutoff valve or supply line under a sink.

Copper — Type K

Pipe & Fittings

The thickest-walled grade of copper pipe, identified by a green stripe or marking. Type K is used for underground water service lines and in applications requiring maximum durability. It is more expensive than Type L or M and is not typically used for interior household supply lines.

You'll hear this when a plumber replaces the water service line from the street to your house.

Copper — Type L

Pipe & Fittings

The most common grade of copper pipe for residential interior supply lines, identified by a blue stripe or marking. It has a medium wall thickness — thicker than Type M, thinner than Type K — and is suitable for both hot and cold water. Most plumbers specify Type L for new work and repairs.

You'll hear this when a plumber quotes a pipe replacement job or when you're buying copper at a hardware store.

Copper — Type M

Pipe & Fittings Code note

The thinnest-walled grade of copper pipe sold for residential use, identified by a red stripe or marking. It is less expensive than Type L and is permitted by code in many jurisdictions for above-ground interior supply lines, but some local codes require Type L. Check with your local building department before using Type M. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this at the hardware store when comparing copper pipe options, or when a plumber specifies which grade to use.

Coupling

Pipe & Fittings

A straight fitting that joins two pipes of the same diameter end-to-end. A standard coupling has a stop inside so the pipes butt up to the center. A slip coupling (also called a repair coupling) has no stop and can slide over a pipe, making it useful for in-line repairs without cutting out a large section.

You'll hear this when a plumber repairs a cracked section of pipe by cutting out the damaged portion and coupling in a new piece.

CPVC

Pipe & Fittings

Chlorinated polyvinyl chloride — a cream or light yellow rigid plastic pipe rated for both hot and cold water supply lines. Unlike standard PVC, CPVC can handle temperatures up to 200 degrees F, making it suitable for hot water distribution. It is joined with a dedicated CPVC solvent cement. Common in homes built from the 1970s through the 1990s.

You'll hear this when a plumber identifies the cream-colored supply pipes in a home from that era, or when you need to repair a hot water supply line without soldering.

Cross connection

Codes & Safety Code note

A cross connection is any actual or potential link between potable water and something that is not potable: a boiler, a lawn-chemical injector, a hose in a pool, a softener drain hard-piped into a sewer. Back siphonage and backpressure can pull or push that contamination into the drinking water. Protection is an air gap or the correct backflow device, not a hope that pressure stays high.

You'll hear this when an inspector points at a hose sitting in a bucket or a boiler tied straight into the house water.

Cross connections are prohibited by the Illinois Plumbing Code except through an approved air gap or backflow preventer matched to the hazard.

Curb stop

Water Supply & Quality Code note

The curb stop is the utility's valve on the water service, usually in a box near the curb or sidewalk, on the street side of the meter. It is how the utility turns a property off. It is not your main shutoff. Operating it, or digging it up, can break a valve the city will bill you for.

You'll hear this when the water has to be off and the valve inside the house will not move.

The curb stop and the service on the street side of the meter are typically utility property under local ordinance. Call the water department. Do not turn that valve as a DIY step.

D

Dielectric union

Pipe & Fittings Code note

A special fitting used where copper and galvanized steel pipes meet. Because copper and steel are dissimilar metals, direct contact causes accelerated corrosion (galvanic corrosion). A dielectric union has a plastic sleeve and rubber washer that electrically isolate the two metals while still making a watertight connection. Required by code at water heater connections in many jurisdictions. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this when a plumber installs or replaces a water heater and connects it to existing galvanized or copper supply lines.

Dip tube

Water Heaters

A plastic tube inside a tank water heater that carries cold incoming water down to the bottom of the tank, where the heating element or burner is. If the dip tube cracks or breaks, cold water mixes with hot at the top and you get lukewarm water even with a full tank.

You'll hear this when a plumber diagnoses a water heater that produces lukewarm water despite the tank being full and the thermostat being set correctly.

Diverter

Fixtures & Parts

A valve that redirects water from one outlet to another — most commonly from a tub spout to a showerhead. In a tub/shower combo, pulling up the knob on the tub spout activates the diverter, which blocks the spout and forces water up to the showerhead. Diverters can also be found in kitchen faucets to switch between the faucet and a side sprayer.

You'll hear this when a plumber diagnoses why water dribbles from the tub spout while the shower is running, or when replacing a tub spout.

Draft hood

Water Heaters Code note

A draft hood is the open metal hat on top of many older gas water heaters, where room air can join the flue gases as they enter the vent. It also lets a downdraft spill out instead of blowing out the burner. If you see soot around it, or the little screws and plastic trim above it look melted, exhaust is spilling. Stop using the heater.

You'll hear this when someone points at the skirt under the vent pipe on an atmospheric heater.

An atmospheric draft hood has to match the heater and the vent. Do not remove it, cap the openings, or replace it with a piece of duct.

Drain snake / auger

Drains / Waste / Vent

A drain snake, or auger, is a flexible cable that you turn to break up or hook a clog. A short hand snake can reach a bathroom branch. A closet auger is made for a toilet. A large power snake for a main line can punch through old pipe and get stuck. Match the tool to the pipe, and do not run one through a chemical-filled drain.

You'll hear this when a plunger is not enough and someone says to snake it.

E

Ejector pump

Drains / Waste / Vent Code note

An ejector pump, often called a sewage ejector, pumps waste from a bathroom or floor drain that sits below the building drain, where gravity cannot carry it out. It lives in a sealed basin, and that basin has to be vented. The discharge has a check valve. This is sewage equipment. Repairing the basin, the vent, or the discharge is a plumber's job.

You'll hear this when a basement bathroom exists and there is a sealed crock with a pump in the floor.

Sewage ejectors, their vents, and their check valves are covered by the Illinois Plumbing Code. A sump pump for groundwater is not a substitute.

Elbow

Pipe & Fittings

A fitting that changes the direction of a pipe run. A 90-degree elbow makes a right-angle turn; a 45-degree elbow makes a gentler turn. Street elbows have one male and one female end, allowing them to connect directly to another fitting without a short pipe nipple between them.

You'll hear this any time a pipe needs to turn a corner — around a wall stud, under a sink, or at the base of a drain stack.

Escutcheon

Fixtures & Parts

The decorative plate or cover that hides the hole in a wall or floor where a pipe or valve stem passes through. You'll see them behind faucet handles, around shower valves, and at the base of supply lines. They're cosmetic — but a missing one lets moisture and pests in.

You'll hear this when a plumber or guide mentions covering the rough-in hole after installing a valve or supply line.

Expansion tank

Water Heaters Code note

A thermal expansion tank is a small tank on the cold inlet of a water heater. When the heater warms the water, the water grows. If a check valve, a PRV, or a meter has made the house a closed system, that growth has nowhere to go and pressure spikes. The expansion tank gives it a cushion. It has to be supported, and its air charge has to match the house pressure.

You'll hear this when a T&P valve drips after the city installs a new meter, or a PRV is added.

Closed potable systems and thermal expansion are addressed in the Illinois Plumbing Code. Many Illinois utilities create a closed system at the meter. Confirm the local requirement before you assume a tank is optional.

F

Faucet washer

Fixtures & Parts

A faucet washer is the small flat rubber disc on the end of a stem in an old compression faucet, the kind with two handles you tighten to shut off. When it wears, the faucet drips from the spout. Newer cartridge faucets do not use this washer. Tightening the handle harder only grooves the seat.

You'll hear this when someone has a two-handle faucet that drips and needs a washer, not a cartridge.

Fill tube (toilet)

Fixtures & Parts

A small flexible tube that connects the fill valve to the overflow tube inside the toilet tank. Its job is to direct a small stream of water into the overflow tube during refill, which replenishes the water in the toilet bowl trap. If the fill tube falls off or is missing, the bowl won't refill after a flush and the trap can dry out, allowing sewer gas in.

You'll hear this when a plumber troubleshoots a toilet where the bowl doesn't refill properly after flushing.

Fill valve

Fixtures & Parts

The mechanism inside a toilet tank that refills the tank with water after a flush. It's connected to the supply line and shuts off automatically when the water reaches the correct level. A hissing toilet or one that runs constantly often has a worn fill valve.

You'll hear this when diagnosing a running or hissing toilet, or when following a toilet repair guide.

First-hour rating

Water Heaters

The first-hour rating is how many gallons of hot water a storage heater can deliver in a busy hour, counting what is already in the tank plus what it can reheat. It is a better comparison than tank gallons alone. A 40-gallon heater with a high first-hour rating can outwork a larger tank with a weak burner.

You'll hear this when two tanks of the same size perform differently.

Fixture unit

Drains / Waste / Vent Code note

A fixture unit is a code number that stands for how much load a fixture puts on the water or drain system. A toilet counts for more drainage fixture units than a bathroom sink. Plumbers add the units up to size drains, vents, and water lines from the tables. It is not a DIY sizing method.

You'll hear this when a remodel adds a bathroom and someone says the existing drain may not have the fixture units for it.

Fixture-unit values and the tables that turn them into pipe sizes are in the Illinois Plumbing Code. Adding a bathroom without checking them is how a remodel fails inspection.

Flame sensor

Water Heaters

A flame sensor is the thin metal rod on many electronic-ignition heaters that proves the burner is actually lit. If it is coated with oxidation, the control will light the burner and then shut the gas off because it cannot see the flame. Cleaning or replacing one still means opening a combustion compartment. Leave it to a plumber unless you are qualified and the power and gas are handled safely.

You'll hear this when a heater clicks, lights, and then shuts down a few seconds later.

Flapper

Fixtures & Parts

The rubber seal at the bottom of a toilet tank that lifts when you flush, letting water rush into the bowl, then drops back down to seal the tank so it can refill. A worn or warped flapper is the most common cause of a running toilet.

You'll hear this when diagnosing a running toilet — the dye-tablet test confirms a leaking flapper.

Float

Fixtures & Parts

The float is the cup or ball on the fill valve that rises with the water and shuts the valve off. Set it so the water stops about an inch below the top of the overflow tube. A float set too high wastes water down the overflow all day.

You'll hear this when someone says to bend the float arm or slide the float cup down.

Floor drain

Drains / Waste / Vent Code note

A floor drain is a drain set in a basement, garage, or laundry floor. It has a trap. If the room smells, the trap may be dry. Pour water in it. If dirty water comes up out of it when you use an upstairs fixture, the clog is downstream and the floor drain is only the place the backup found daylight.

You'll hear this when a basement smells, or when a backup shows up on the floor.

Floor-drain traps that would otherwise go dry often need a trap primer under the Illinois Plumbing Code. A primer keeps the seal. A bucket of water now and then is a stopgap, not the code fix.

Flow rate

Water Supply & Quality

Flow rate is how much water moves in a given time, usually gallons per minute. A faucet can have decent pressure and still have a low flow rate because an aerator, a cartridge, or a partly closed stop is in the way. Shower valves and tankless heaters both have minimum and maximum flow rates they were designed around.

You'll hear this when a shower feels weak but a gauge on the hose bibb says the pressure is fine.

Flue

Water Heaters Code note

The flue is the passage that carries combustion exhaust out of a gas water heater. Inside the tank it is the tube up the center. Above the tank it continues as the vent pipe. A blocked, rusted, or disconnected flue can spill carbon monoxide into the room. Soot, melted plastic, or a vent that has come apart is a stop-using-it problem.

You'll hear this when someone looks at the pipe leaving the top of a gas heater.

Vent and chimney rules for gas water heaters are in the Illinois Plumbing Code and the fuel-gas rules your city has adopted. A vent is sized and sloped. It is not any metal pipe headed vaguely upward.

Flush handle and chain

Fixtures & Parts

The handle on the outside of the toilet tank and the chain (or lift wire) that connects it to the flapper inside. Pressing the handle pulls the chain, which lifts the flapper and starts the flush. Common problems: a chain that's too short (flapper won't seal), too long (chain gets caught under the flapper), or a broken handle.

You'll hear this when a toilet won't flush or the handle feels loose — both are usually a quick fix involving the chain length or handle nut.

Flush valve

Fixtures & Parts

The large valve assembly at the center of the toilet tank that releases water into the bowl when you flush. It includes the flapper (or a tower/canister in newer designs), the overflow tube, and the seat the flapper seals against. The entire flush valve can be replaced if the seat is pitted or cracked and a new flapper alone won't stop a leak.

You'll hear this when a plumber says the flapper seat is damaged and the whole flush valve needs replacing, not just the flapper.

Frozen pipe

Common Problems

A frozen pipe is a water line that has turned to ice, usually on an outside wall, in a crawlspace, or at a hose bibb. The faucet runs weak or not at all. The danger is the split that shows up when the ice thaws. Open the faucet, warm the room, and warm the pipe gently. Never use an open flame. If the pipe has already split, shut the water off before it thaws all the way.

You'll hear this when a faucet on an exterior wall stops running on a bitter night.

G

Galvanized pipe

Pipe & Fittings

Steel pipe coated with zinc to resist corrosion, used for water supply lines in homes built before the 1960s. Over decades, the zinc coating wears away from the inside, and the pipe corrodes and accumulates mineral scale, progressively reducing water flow. Galvanized supply lines that are more than 40-50 years old are typically near the end of their service life and are a common cause of low water pressure throughout a house.

You'll hear this when a plumber inspects an older home and recommends repiping, or when you notice house-wide low pressure that gets worse over time.

Gasket

Fixtures & Parts

A flat seal — usually rubber, foam, or fiber — placed between two surfaces to prevent leaks. You'll find gaskets under faucet bases, inside hose connections, and between toilet tanks and bowls. When a gasket hardens or cracks with age, it leaks.

You'll hear this when a plumber identifies the source of a leak at a connection point between two flat surfaces.

Gate valve

Pipe & Fittings

A gate valve uses a wheel and several turns to lower a gate across the pipe. It is common on older main shutoffs. It is meant to be all the way open or all the way closed. Leaving it half open wears the gate, and forcing a stuck one can snap the stem.

You'll hear this when the main shutoff is a round wheel that takes many turns.

GFCI

Codes & Safety Code note

A GFCI, or ground-fault circuit interrupter, is an electrical device that cuts power almost instantly if current leaks out of the circuit, which is what can happen when water and electricity meet. Outlets near sinks, in bathrooms, garages, and unfinished basements are commonly required to be GFCI-protected. A disposal or a pump that suddenly has no power is often a tripped GFCI, not a dead motor.

You'll hear this when an outlet near the sink has Test and Reset buttons, or a disposal is silent.

GFCI rules come from the electrical code your city has adopted, often a version of the National Electrical Code, not from the plumbing code. Do not bypass a GFCI that keeps tripping.

Ghost flushing

Common Problems

Ghost flushing is a toilet that refills itself for a few seconds when nobody has used it. A slow leak at the flapper drops the tank level until the fill valve wakes up. The dye test confirms it: color in the tank, then color in the bowl without a flush. It wastes water quietly and it moves the meter.

You'll hear this when a toilet runs in the middle of the night.

GPM (gallons per minute)

Water Supply & Quality

The measure of how much water flows through a fixture or appliance per minute. Showerheads are rated in GPM — federal law caps new showerheads at 2.5 GPM. Low-flow fixtures use 1.5-2.0 GPM. A sudden drop in GPM at one fixture usually points to a clogged aerator or a partially closed valve.

You'll hear this when comparing fixtures at a hardware store, or when a plumber measures your flow rate to diagnose a pressure problem.

Grade / slope

Drains / Waste / Vent Code note

Grade, or slope, is how much a drain falls as it runs. Too little fall and solids sit in the pipe. Too much fall and liquids outrun the solids, which also leaves a clog. A common minimum for smaller drain lines is 1/4 inch of fall per foot. That is a rule of thumb you confirm against the code section for your pipe size, not a number to invent.

You'll hear this when a drain is being hung and someone checks the fall with a level.

Minimum drainage slope by pipe size is set in the Illinois Plumbing Code. Local inspectors measure it. A pipe that looks 'downhill enough' can still be flat.

Gurgling drain

Common Problems

A gurgling drain is air being pulled through water because the vent is blocked, the line is partly clogged, or a trap is being siphoned. One fixture can be a local vent or a partial clog. A toilet that gurgles when the washer drains is a warning of a main-line problem.

You'll hear this when a sink glugs, or a toilet bubbles while another fixture drains.

H

Hard water

Water Supply & Quality

Hard water has a lot of dissolved calcium and magnesium. It leaves scale on heaters and shower doors, spots on fixtures, and uses more soap. It is not unsafe by itself. A water test tells you the hardness number. A softener is optional equipment, not a repair for a leak or a clogged aerator you have not cleaned yet.

You'll hear this when fixtures crust over and the water heater pops.

Heating element

Water Heaters

A heating element is the electric rod that heats water inside an electric tank. Most tanks have an upper and a lower element. The lower one does most of the work and fails first, which looks like hot water that runs out fast. Elements run on 240 volts. The breaker has to be off, and proved off, before a cover comes off.

You'll hear this when an electric heater has power and still does not make hot water.

Hose bibb

Fixtures & Parts

A hose bibb is an outdoor faucet, or any faucet with a hose thread. A frost-proof bibb has a long stem so the valve seat sits inside the warm wall. Those only stay frost-proof if you disconnect the hose in winter. A hose left on traps water in the barrel and it can split.

You'll hear this when someone talks about the outside faucet or a sill cock.

House trap

Drains / Waste / Vent Code note

A house trap is a trap on the building drain, usually near where the sewer leaves an older house, sometimes with a fresh-air inlet. Many older Illinois homes still have one. It was meant to keep sewer gas out. It also catches debris and can cause a whole-house backup. Do not remove one on your own. The venting of the whole house may have been designed around it.

You'll hear this when an older basement has a trap with two cleanout plugs on the main drain.

Removing or altering a house trap changes the drainage system. That is permit work under the Illinois Plumbing Code and local ordinance, done by a licensed plumber or a qualifying owner-occupant.

Hydro jetting

Drains / Waste / Vent

Hydro jetting uses high-pressure water from a special hose to scour a sewer line. It can remove grease and roots that a cable only punches a hole through. It can also damage a pipe that is already cracked or brittle. It is a plumber's machine, chosen after a camera has seen what the pipe is made of. A pressure washer is not a jetter.

You'll hear this when cabling a greasy kitchen line or a root-filled lateral did not last.

I

Igniter

Water Heaters

An igniter lights the burner on a heater that does not have a standing pilot. Hot-surface igniters glow. Spark igniters click. When an igniter fails, you get no flame and often an error code. The part is inexpensive. Getting to it safely, and confirming the gas valve still shuts off, is the part that belongs with a technician.

You'll hear this when a gas heater tries to start and never lights, and there is no pilot to relight.

Iron filter

Water Supply & Quality

An iron filter removes dissolved or particulate iron from well water so fixtures do not stain orange and the softener resin is not ruined. Some filters use air, some use media that needs a regenerant. Iron bacteria, the slimy kind, is a different problem and a filter alone may not stop the smell. Test the water before you buy a tank.

You'll hear this when well water stains sinks orange or a softener keeps failing.

L

Lavatory

Fixtures & Parts

Lavatory is the code word for a bathroom sink. It is not the bathroom itself. When a code table lists fixture units for a lavatory, it means that sink, including its faucet, drain, and trap.

You'll hear this when a permit form says lavatory and means the bathroom basin.

Licensed plumber (Illinois, 225 ILCS 320)

Codes & Safety Code note

In Illinois, plumbing is regulated by the Illinois Plumbing License Law, 225 ILCS 320. A licensed plumber has met the state's requirements and can pull permits and do plumbing work. There is a narrow exception for an owner-occupant or lessee-occupant of a single-family home, or an owner building a single-family home they will occupy, to do the plumbing on that home. The work still has to meet the Illinois Plumbing Code (77 Ill. Adm. Code 890) and be inspected where the city inspects. They cannot hire an unlicensed person to help. It has to be their real home, with the intent to live there at least six months. A rental, a second house, or a friend's 'help' does not fit that exception.

You'll hear this when a job needs a permit, a gas line, or a change to a drain or vent.

This is general information, not legal advice. Read 225 ILCS 320/3 and ask the local building department. Cities can require permits even when the state allows an owner-occupant to do the work.

M

Main sewer line

Drains / Waste / Vent

The main sewer line is the pipe that carries the whole house's waste off the property. People use the words for the building drain under the basement floor and for the lateral in the yard. A clog here backs up the lowest fixtures and makes toilets gurgle. It is diagnosed with a camera, not with a bottle of cleaner.

You'll hear this when every drain is slow and the floor drain in the basement is the first to overflow.

Main shutoff valve

Water Supply & Quality

The main shutoff valve turns off water to the whole house. It is on the house side of the water meter, where the line comes through the wall, or in a utility room. The valve at the curb on the street side of the meter is the utility's. Know which is which before a leak.

You'll hear this when someone says to kill the water to the house.

Mixing valve

Fixtures & Parts Code note

A valve that blends hot and cold water to deliver a set temperature. Thermostatic mixing valves (TMVs) are installed at water heaters or point-of-use to prevent scalding — they're required by code in certain applications such as care facilities. A simpler mixing valve is built into every single-handle faucet and shower valve. This is general information; Illinois Plumbing Code and local amendments govern specific requirements.

You'll hear this when a plumber installs anti-scald protection at a water heater, or when discussing shower valve types.

N

Nipple

Pipe & Fittings

A nipple is a short piece of pipe threaded on both ends. Water heaters often have steel nipples in the top connections. When those rust through, the leak looks like it is coming from the tank. Replacing a nipple on old galvanized pipe can crack the next fitting.

You'll hear this when a leak is at a short threaded piece rather than a long run of pipe.

No-hub coupling (Fernco-style)

Pipe & Fittings

A flexible rubber sleeve with stainless-steel clamps used to join two pipe ends without threading or gluing. Originally designed for cast iron (no-hub) pipe, these couplings are now widely used to connect pipes of different materials (cast iron to PVC, for example) or to make repairs without cutting long sections. The Fernco brand is so common that the style is often called a Fernco coupling.

You'll hear this when a plumber repairs a section of cast iron drain pipe or connects old and new drain materials.

O

O-ring

Fixtures & Parts

A small circular rubber seal used inside faucets, valves, and cartridges to prevent water from leaking around a moving part. O-rings are sized by their inner diameter and cross-section thickness. A worn or flattened O-ring is a common cause of leaks at the base of a faucet spout or around a valve stem.

You'll hear this when a plumber disassembles a faucet and finds the source of a leak is a dried-out rubber ring rather than the cartridge itself.

Overflow tube

Fixtures & Parts

The vertical tube in the center of the toilet tank that acts as an emergency drain. If the fill valve fails to shut off and the water level rises too high, water spills into the overflow tube and drains into the bowl rather than overflowing onto the floor. The water level in the tank should sit about an inch below the top of the overflow tube. If water is constantly trickling into the bowl through the overflow tube, the fill valve needs adjustment or replacement.

You'll hear this when diagnosing a running toilet — if water is running into the bowl but the flapper is fine, the water level may be too high and spilling over the overflow tube.

P

P-trap

Drains / Waste / Vent

The curved, P-shaped pipe section under every sink, tub, and shower drain. It holds a small amount of water at all times, which creates a seal that blocks sewer gases from entering your home. If a drain smells bad, the trap may have dried out — running water for a minute usually fixes it.

You'll hear this when a plumber diagnoses a sewer smell under a sink, or when following a guide to replace the drain assembly.

Packing nut

Fixtures & Parts

A packing nut is the nut under the handle of an older faucet or a valve stem. It compresses packing or an O-ring so water does not weep up the stem. Snugging it a fraction of a turn can stop a small weep. Cranking it makes the handle hard to turn and can damage the stem.

You'll hear this when a handle leak is fixed without taking the whole faucet apart.

PEX

Pipe & Fittings

Cross-linked polyethylene — a flexible plastic tubing used for water supply lines. It's color-coded (red for hot, blue for cold), easy to route through walls, and resistant to freezing damage. PEX has largely replaced copper in new residential construction because it's faster and cheaper to install.

You'll hear this when a plumber quotes a repipe job or when you see flexible colored tubing in a newer home.

PEX-A

Pipe & Fittings

The most flexible grade of PEX tubing, made using the Engel (peroxide) method. PEX-A has a memory — if it kinks, you can apply heat and it will return to its original shape. It uses expansion-style fittings (the pipe is expanded, a ring is slid on, and the pipe contracts around the fitting as it cools). PEX-A is generally considered the highest quality PEX and is the only type that can be repaired with a heat gun after a kink.

You'll hear this when a plumber specifies Uponor or Rehau brand PEX, or when comparing PEX types at a supply house.

PEX-B

Pipe & Fittings

A grade of PEX tubing made using the silane (moisture cure) method. It is slightly stiffer than PEX-A and does not have shape memory — a kink is permanent. PEX-B uses crimp or clamp-style fittings, which are less expensive than expansion fittings. It is the most widely available type of PEX at retail hardware stores and is suitable for most residential supply line applications.

You'll hear this when buying PEX at a home center — most retail PEX is PEX-B. Crimp rings and a crimp tool are the standard connection method.

Phantom water use

Common Problems

Phantom water use is water the meter records when you cannot see a faucet open. The usual causes are a ghost-flushing toilet, a softener stuck in regeneration, an ice maker, an irrigation valve, or a hidden leak. Isolate the toilets and watch the meter. If it still moves, the leak is elsewhere and it is time to call.

You'll hear this when a water bill jumps and nobody can find a drip.

Pinhole leak

Common Problems

A pinhole leak is a tiny hole in a pipe, often copper, that sprays a fine mist or weeps. Pinholes in several places usually mean the pipe is failing from the inside, from water chemistry or from erosion. Fixing one pinhole and leaving the rest of a bad run is a short-term patch. A pinhole on a gas line is not a plumbing patch at all. Leave the building if you smell gas.

You'll hear this when a copper line has a green crust and a wet spot in one tiny place.

Pipe dope (pipe joint compound)

Pipe & Fittings

A paste-like sealant applied to threaded pipe connections to fill the small gaps between threads and prevent leaks. It is used on metal threaded fittings — often in combination with Teflon tape — and on some plastic fittings where the manufacturer allows it. Not all pipe dopes are compatible with all materials; always check the label for compatibility with plastic, gas lines, or potable water.

You'll hear this when a plumber assembles threaded galvanized, brass, or iron fittings, or when connecting a gas line fitting (use only gas-rated pipe dope on gas connections).

Plumber's putty

Fixtures & Parts

Plumber's putty is a soft compound used to seal the rim of some drains and basket strainers to the sink. It is not a thread seal, and it is not for every surface. Some plastic sinks and some stone stains from the oils in putty. Those call for the maker's silicone sealant instead.

You'll hear this when a strainer is being set in a kitchen sink.

Plumbing inspection

Codes & Safety Code note

A plumbing inspection is the check, by the city or the state, that the work matches the code. Rough-in inspections happen before the wall is closed. Final inspections happen when the fixtures are set. In Illinois, plumbing inspection is done by a licensed plumber acting for the authority. Covering work before it is inspected is how floors get opened back up.

You'll hear this when a permit is issued and someone schedules the rough-in before the drywall.

Who may inspect plumbing, and when, comes from the Illinois Plumbing License Law and the local program. Do not skip an inspection because the leak is already fixed.

Plumbing permit

Codes & Safety Code note

A plumbing permit is the city's permission to do regulated plumbing work, followed by an inspection. Replacing an aerator does not need one. Replacing a water heater, moving a fixture, or opening a drain or vent usually does. In Illinois, a city that requires a plumbing permit is not supposed to issue it unless the applicant is licensed or is the owner-occupant doing qualifying work on their own single-family home.

You'll hear this when a job is bigger than a faucet washer and someone asks whether the town wants a permit.

Permit rules are local ordinances on top of the Illinois Plumbing License Law (225 ILCS 320) and the Illinois Plumbing Code (77 Ill. Adm. Code 890). Call the building department. A hardware-store receipt is not a permit.

Pop-up drain

Fixtures & Parts

The drain stopper assembly in a bathroom sink that opens and closes via a pivot rod connected to the lift rod behind the faucet. Pulling up the lift rod pushes the stopper down to close the drain; pushing the lift rod down lifts the stopper to open it. The pivot rod passes through the drainpipe and connects to the stopper via a clevis strap. Pop-up assemblies are a common source of slow drains when hair and soap accumulate on the pivot rod.

You'll hear this when a plumber cleans a slow bathroom sink drain or adjusts a stopper that won't stay open or closed.

Popping or rumbling water heater

Common Problems

Popping or rumbling from a tank water heater is sediment at the bottom, flashing to steam when the burner or element comes on. A careful flush can quiet it. Rumbling plus a gas smell, soot, or water on the floor is not a flush. Shut the heater down the safe way and call a plumber.

You'll hear this when a heater sounds like a kettle while the burner is on.

Potable water

Codes & Safety Code note

Potable water is water that is safe to drink. The pipes that carry it have to stay separate from drains, boilers, and anything that could flow backward into them. A hose in a bucket, a heater without protection, or a cross connection can make potable water not potable.

You'll hear this when someone says a line has to stay on the potable side of a backflow preventer.

Protection of the potable water supply is covered in the Illinois Plumbing Code, including 77 Ill. Adm. Code 890.1130. Local water suppliers add their own backflow rules.

Power vent

Water Heaters Code note

A power vent uses a fan to push or pull exhaust out of a gas water heater, which is why some heaters can vent through a sidewall instead of a chimney. The fan has to prove it is running before the gas opens. A failed fan, a blocked intake, or a frozen exterior termination will shut the heater down. This is not a part to bypass.

You'll hear this when a gas heater has a blower on top and a plastic vent pipe.

Power-vent materials, length, and termination clearances are listed by the manufacturer and limited by code. PVC vent pipe on a heater is not the same as PVC drain pipe, and not every heater is allowed to use it.

Pressure switch

Water Supply & Quality

The pressure switch tells the well pump when to start and stop based on the pressure in the tank. A common setting is something like 30 psi on and 50 psi off, but the right numbers depend on the tank and the system. Burned contacts chatter or do nothing. Do not raise the setting to 'get more pressure.' You can over-pressurize the house and hide a failing pump.

You'll hear this when someone points at the small gray box near the pressure tank.

Pressure tank

Water Supply & Quality

A pressure tank stores water under air pressure so the well pump does not have to start every time you open a tap. Inside, a bladder separates air from water. When the bladder fails, the tank waterlogs and the pump short-cycles. Checking the air charge is done with the power off and the water drained, following the tank's label.

You'll hear this when a well pump clicks on and off every few seconds.

Pressure-balance valve

Fixtures & Parts Code note

A shower valve that automatically maintains a constant ratio of hot to cold water pressure, preventing sudden temperature spikes when a toilet is flushed or a dishwasher starts. Required by code in all new shower installations in the United States. It does not maintain a precise temperature — it only balances pressure. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this when a plumber installs a new shower valve or explains why your old shower scalds you when someone flushes a toilet.

PRV (pressure reducing valve)

Water Supply & Quality

A valve installed on the main water supply line that reduces the incoming water pressure from the street to a safe level for household plumbing — typically 50-80 PSI. High water pressure stresses pipes, fittings, and appliances. If your PRV fails, you may notice banging pipes, leaking fixtures, or a water heater T&P valve that keeps tripping.

You'll hear this when a plumber tests your water pressure and finds it above 80 PSI, or when diagnosing unexplained fixture leaks throughout the house.

PSI

Water Supply & Quality Code note

PSI is pounds per square inch, the unit on a water-pressure gauge. Household systems are often kept somewhere in a middle band so fixtures work and the water heater's relief valve stays quiet. The legal maximum at the fixture comes from the code, not from how strong you would like the shower. Measure at a hose bibb with a gauge before anyone adjusts a PRV.

You'll hear this when someone asks what the house pressure is.

The Illinois Plumbing Code limits maximum water pressure. If city pressure is higher, a PRV is how it gets reduced. Do not set a valve by feel.

Push-to-connect fitting (SharkBite-style)

Pipe & Fittings Code note

A fitting that creates a watertight connection simply by pushing the pipe into the fitting — no soldering, gluing, or crimping required. A stainless-steel grab ring and an O-ring inside the fitting grip and seal the pipe. Compatible with copper, PEX, CPVC, and PE-RT pipe. SharkBite is the most recognized brand. Push-to-connect fittings are widely used for repairs and emergency fixes; some plumbers prefer not to use them inside walls for permanent installations, though they are code-compliant in most jurisdictions. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this when a plumber makes a quick repair without a torch, or when a DIY guide recommends them for a no-solder fix.

PVC

Pipe & Fittings

Polyvinyl chloride — a rigid white or cream-colored plastic pipe used for drain, waste, and vent lines in most homes built after the 1970s. It's lightweight, inexpensive, and easy to cut and glue. PVC is not rated for hot water supply lines — use CPVC or PEX for those.

You'll hear this when a plumber identifies the white drain pipes in your home, or when buying drain fittings at a hardware store.

R

Recirculation pump

Water Heaters

A recirculation pump moves hot water around a loop so a far faucet gets hot sooner. It can run on a timer or on demand. A loop that is installed wrong wastes energy, and a missing check valve can let hot water migrate into the cold line. Adding one to an existing house is a design job, not a plug-in accessory, unless the kit is listed for that exact use.

You'll hear this when someone is tired of waiting for hot water at a distant bathroom.

Reducer

Pipe & Fittings Code note

A reducer is a fitting that changes pipe size, from 3/4 inch to 1/2 inch for example. On a water line, stepping down too early is a common reason a fixture is weak. On a drain, you cannot reduce size in the direction of flow. Waste has to see the same size or a larger size as it moves downstream.

You'll hear this when two pipes of different sizes have to meet.

Drainage piping is not reduced in the direction of flow under the Illinois Plumbing Code. A smaller pipe downstream is a clog and a code problem.

Relief valve discharge pipe

Water Heaters Code note

The relief valve discharge pipe is the pipe on the outlet of a T&P valve. It carries a hot release down to a safe, visible place. It should be the full size of the valve outlet, slope downhill, have no valve and no cap, and should not be threaded on the open end in a way that invites someone to plug it. Ending it in a drain with a direct connection is wrong.

You'll hear this when a heater has a pipe aimed at the floor from the relief valve, or when that pipe is missing.

Discharge termination, size, and material are in the Illinois Plumbing Code and the valve listing. The pipe ends where a release will be noticed and will not scald someone. Confirm the exact rule locally before you change one.

Resin

Water Supply & Quality

Resin is the bead media inside a water softener that grabs calcium and magnesium. It lasts for years unless iron or chlorine fouls it. When the water turns hard again and the brine tank is full of salt, fouled or depleted resin is one of the causes. Replacing resin means opening the tank. The softener maker's procedure matters.

You'll hear this when a softener is old and the water tests hard even after a regeneration.

Reverse osmosis (RO)

Water Supply & Quality Code note

A reverse osmosis system pushes water through a membrane to remove a wide range of dissolved contaminants. The under-sink unit makes a small stream of treated water and sends a larger stream of reject water to the drain. It needs an air gap on that drain connection. It is a drinking-water tap, not a whole-house softener, unless it is a much larger system.

You'll hear this when someone wants a separate drinking-water faucet.

The drain from an RO unit has to protect the potable water and the drainage system. An air gap is the usual requirement. Do not tee the reject line directly into a drain without one.

Root intrusion

Drains / Waste / Vent

Root intrusion is tree roots entering a sewer through a crack or a separated joint, then growing into a mat that catches paper. The line will back up, get cabled clear, and clog again because the roots and the broken joint are still there. A camera shows the roots. A repair or a lining, where it is allowed, is the lasting fix.

You'll hear this when an older yard has a large tree and the sewer clogs every year.

Rotten egg smell

Common Problems

A rotten egg smell from the water, not from a drain, is usually hydrogen sulfide. It shows up in some wells, in a water heater where bacteria are reacting with the anode rod, or when hot water smells and cold does not. If the smell is in the air of the room and you did not run the water, treat it as a gas leak and leave. Hot-water-only smell is a heater discussion, not a reason to ignore a gas odor.

You'll hear this when only the hot water smells like sulfur.

Rough-in

Codes & Safety Code note

Rough-in is the piping installed before the walls and floors are closed, including the drains, vents, and supplies set at the right height for each fixture. It is also the word for the measured distance a toilet drain sits off the wall, commonly 12 inches. Buy a toilet that matches the rough-in you have.

You'll hear this when someone asks, 'What's the rough-in?' before you order a toilet.

Rough-in work is inspected in most Illinois cities before the wall is closed. Covering it first is how a project gets opened back up.

RPZ valve

Codes & Safety Code note

An RPZ is a reduced-pressure-zone backflow assembly. It is the heavy device, with relief ports in the middle, used where a serious hazard could push back into the drinking water. In Illinois these assemblies are tested when they are installed and at least once a year by a cross-connection control device inspector. A drip from the relief port means it needs service. Do not plug the port.

You'll hear this when a commercial building, a boiler, or an irrigation system has a backflow assembly that has to be tested.

Illinois requires RPZ, RPDA, double-check, and double-check-detector assemblies to be tested by a CCCDI before use and at least annually. Records stay on site. See 77 Ill. Adm. Code 890.1130.

S

S-trap

Drains / Waste / Vent Code note

An S-trap is a drain that drops out of a fixture, makes an S curve, and falls into the floor. The water racing down the second curve can suck the trap dry, and then sewer gas comes in. You still see them under old sinks. Replacing an S-trap with another S-trap copies the problem. The real fix is a P-trap into a vented drain.

You'll hear this when a trap goes into the floor instead of the wall and the room smells after the sink drains.

S-traps are not an approved way to trap a fixture under the Illinois Plumbing Code. Correcting one means a proper trap arm and a vent, which is usually a permit job.

Sanitary tee

Pipe & Fittings

A drain fitting shaped like the letter T, but with a curved (swept) branch inlet rather than a straight one. The curve directs flow smoothly in the direction of drainage, reducing turbulence and the chance of blockages. A sanitary tee is used where a branch drain connects to a vertical stack. It must be installed in the correct orientation — the swept inlet must face down in the direction of flow.

You'll hear this when a plumber adds a new drain branch to an existing stack, or when distinguishing it from a regular tee (which is not permitted in drain lines).

Schedule 40

Pipe & Fittings

Schedule 40 is a wall thickness for plastic and steel pipe. Most household PVC and ABS drain pipe is Schedule 40. The number is not a brand, and it is not a pressure rating by itself. Two white pipes can both say Schedule 40 and still be meant for different jobs.

You'll hear this when a store label says Sch 40 PVC and you need to know if it is drain pipe or pressure pipe.

Seat and spring

Fixtures & Parts

Small internal components found in ball-type faucets (like Delta single-handle faucets). The spring holds the rubber seat against the ball, creating a watertight seal at each water port. When a ball faucet drips, worn seats and springs are usually the cause. They are inexpensive and sold in repair kits along with the ball and O-rings.

You'll hear this when a plumber or guide walks you through rebuilding a ball-type faucet — the seats and springs are the first things to replace.

Sediment

Water Heaters

Minerals — mainly calcium and magnesium — that settle out of hard water and accumulate at the bottom of a tank water heater over time. A thick layer of sediment insulates the water from the burner, makes the heater work harder, and shortens its life. Flushing the tank once a year removes it.

You'll hear this when a plumber recommends annual water heater maintenance, or when you notice rumbling or popping sounds from your water heater.

Sediment filter

Water Supply & Quality

A sediment filter is a cartridge or a spin-down screen that catches sand and rust before they reach faucets, a softener, or a water heater. When it clogs, pressure drops in the whole house or on the cold-water line it feeds. Changing a cartridge means shutting the valves around the housing and having a towel ready. Match the micron rating to the problem. A filter that is too fine clogs constantly.

You'll hear this when aerators fill with sand after the city works on a main.

Sediment flush

Water Heaters

A sediment flush is draining mineral and rust out of the bottom of a tank water heater through the drain valve. It can quiet popping and give you back some capacity. The heat stays off until the tank is full again. If the drain valve will not close, stop. A tankless heater is not flushed this way.

You'll hear this when a tank pops and rumbles as the burner fires.

Sewer camera inspection

Drains / Waste / Vent

A sewer camera inspection sends a video camera down the drain so you can see a break, a belly, roots, or an offset joint instead of guessing. It is the right first step when backups keep returning. Ask for the recording. A camera also helps show whether the problem is on your lateral or in the public main.

You'll hear this when a clog comes back and someone wants to see the pipe before digging.

Sewer gas smell

Common Problems

A sewer gas smell is the musty, rotten odor that comes out of a drain when a trap is dry, siphoned, or missing, or when a vent is blocked. It is not the same as a gas-leak odor, but people mix them up. If you are not sure, leave and call the gas utility. If the smell is clearly at one drain and pouring water in the trap stops it, the trap had gone dry. Find out why it went dry.

You'll hear this when a basement floor drain or a rarely used shower smells.

Sewer lateral

Drains / Waste / Vent Code note

The sewer lateral is the pipe from your house to the city sewer main, sometimes called the building sewer once it is outside. Who owns and repairs which portion varies by city. Some towns own only the main in the street. The homeowner often owns the lateral all the way to that main. Ask before you assume.

You'll hear this when a backup is in the yard, not in a bathroom, and someone mentions the line to the street.

Ownership of the lateral is a local ordinance question. The Illinois Plumbing Code still governs how a building sewer is built. Call your sewer utility before you dig or assign blame.

Short cycling

Common Problems

Short cycling is a pump or a heater turning on and off too often. On a well, it usually means a waterlogged pressure tank. On a water heater, it can mean sediment, a thermostat problem, or a tank that is oversized for a small hot-water draw. Letting a pump short-cycle burns the motor. Do not raise a pressure switch to hide it.

You'll hear this when a well pump clicks every few seconds, or a heater fires in short bursts.

Shutoff valve

Water Supply & Quality

A valve that stops water flow to a specific fixture or to the whole house. Under-sink shutoff valves let you cut water to a faucet without turning off the main supply. The main shutoff valve stops all water to the house — knowing where it is before an emergency is one of the most important things a homeowner can do.

You'll hear this any time a repair requires stopping water flow — the first step in almost every plumbing repair guide.

Slip nut

Fixtures & Parts

A large plastic or metal nut used to tighten slip-joint drain connections — the kind found on P-traps and drain tailpieces under sinks. Slip nuts thread onto a fitting and compress a nylon washer to create a seal. They can be tightened by hand and then snugged with pliers. Overtightening cracks plastic slip nuts; undertightening causes drips.

You'll hear this when a plumber assembles or adjusts the drain assembly under a sink, or when you're replacing a P-trap.

Soil stack

Drains / Waste / Vent

The soil stack is the vertical pipe that carries toilet waste, and often other fixture waste, down through the house and out through the roof as a vent. A gurgle in several upstairs fixtures when a lower fixture drains can mean trouble in this stack or its vent.

You'll hear this when someone talks about the main stack in the wall behind the toilet.

Standpipe

Drains / Waste / Vent Code note

In a house, a standpipe is the vertical drain pipe that a washing machine hose discharges into. It has to be tall enough that the machine does not siphon, and it needs a trap. It is not the fire-protection standpipe in a commercial building, which is a different system entirely.

You'll hear this when a washer dumps onto the floor because the hose jumped out of the pipe.

Washer standpipes have height and trap requirements in the Illinois Plumbing Code. A hose stuffed into a floor drain is not the same thing.

Stem

Fixtures & Parts

The threaded shaft inside an older compression-style faucet that moves up and down when you turn the handle, pressing a rubber washer against a seat to stop water flow. Stem faucets (also called compression faucets) were standard before cartridge and ball-type faucets became common. A dripping stem faucet usually needs a new rubber washer at the bottom of the stem.

You'll hear this when repairing an older two-handle faucet — the kind where you turn the handle multiple times to open and close the water.

Sump pump

Drains / Waste / Vent Code note

A sump pump sits in a pit and pumps groundwater out from under a basement. It is not a sewage pump. The discharge has to leave the house and get far enough away that the water does not run straight back to the foundation. A check valve stops the discharge pipe from dumping back into the pit. Backup power matters because storms are when the pump is needed and when the power fails.

You'll hear this when a basement takes on groundwater, not sewage.

Where a sump may discharge, and whether a backup pump is required, is often a local stormwater rule on top of the plumbing code. Do not pipe a sump into the sanitary sewer unless the city specifically allows it.

Supply line

Water Supply & Quality

The flexible braided hose that connects a shutoff valve to a faucet, toilet, or appliance. Supply lines are under constant pressure and can fail without warning — especially older rubber-core lines. Stainless-steel braided lines are more reliable and worth the small upgrade cost.

You'll hear this when a plumber recommends replacing old supply lines as a preventive measure, or when one fails and causes a flood under a sink.

Supply stop

Fixtures & Parts

A shutoff valve on the supply line between the wall and a fixture — the valve you turn off before replacing a faucet or toilet. Supply stops come in straight (inline) and angle (90-degree) configurations. The angle stop is the most common type under sinks and toilets. Also called an angle stop, fixture shutoff, or simply a stop valve.

You'll hear this when a plumber or guide tells you to turn off the supply stop before starting a repair.

Sweat fitting (soldered fitting)

Pipe & Fittings Code note

A copper fitting joined to copper pipe by soldering — heating the joint with a torch and flowing solder into the gap by capillary action. Sweating a joint is the traditional method for copper supply lines and produces a very durable, permanent connection. It requires a torch, solder, flux, and some practice. Lead-free solder is required by code for potable water systems. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this when a plumber repairs or installs copper supply lines, or when a guide says to sweat the fitting.

Sweating pipes

Common Problems

Sweating pipes are cold pipes covered in condensation, not pipes that are leaking. Humid air hits the cold surface and drops water. The meter does not move if no fixture is open. Foam insulation on the cold line stops the sweating. A drip at one joint, with the meter moving, is a leak. Do not confuse the two.

You'll hear this when a basement looks wet under cold-water lines in the summer.

T

T&P valve (temperature and pressure relief valve)

Water Heaters

A safety valve on a water heater that automatically opens to release water if the temperature or pressure inside the tank gets dangerously high. It's a critical safety device — never cap it, remove it, or replace it with a plug. If it's dripping or discharging, call a licensed plumber: it means something is wrong with the system.

You'll hear this in any water heater safety discussion — it is the single most important safety device on a tank water heater.

Tailpiece

Fixtures & Parts

The straight vertical pipe that connects the drain opening of a sink (or the basket strainer in a kitchen sink) to the P-trap below. It is typically 1-1/4 inch for bathroom sinks and 1-1/2 inch for kitchen sinks. Tailpieces are usually chrome-plated brass or PVC and are held in place with a slip nut.

You'll hear this when a plumber assembles the drain under a sink, or when you're replacing a P-trap and need to measure the drop from the drain to the trap.

Tank bolts

Fixtures & Parts

The bolts that hold the toilet tank to the bowl. They pass through holes in the bottom of the tank and the back of the bowl, and are sealed with rubber washers and gaskets. Leaks at the base of the tank (not the bowl) are often caused by deteriorated tank bolt washers or a cracked tank-to-bowl gasket. Replacement kits are inexpensive and widely available.

You'll hear this when a plumber diagnoses a leak between the toilet tank and bowl, or when the tank rocks side to side.

Tankless water heater

Water Heaters

A tankless water heater heats water as it flows through a heat exchanger. There is no storage tank. It needs enough gas or electrical power, a clear vent, and a flow rate above its minimum or it will not fire. Scale in the heat exchanger is the common reason one runs lukewarm. Repairs inside the unit are a technician's job.

You'll hear this when the hot water never 'runs out' in the old way, but the unit shows an error code instead.

Tee

Pipe & Fittings

A T-shaped fitting with three openings used to split or combine flow — one inlet and two outlets, or two inlets and one outlet. In supply lines, a tee splits flow to two fixtures. In drain lines, a sanitary tee (with a swept inlet) is required rather than a standard tee. Reducing tees have different-sized openings to connect pipes of different diameters.

You'll hear this when a plumber adds a branch to an existing supply or drain line.

Teflon tape (PTFE tape)

Pipe & Fittings

A thin white (or yellow for gas) tape wrapped around the male threads of a pipe fitting before assembly to lubricate the threads and fill microscopic gaps, creating a leak-free seal. Wrap it clockwise (in the direction you'll tighten the fitting) so it doesn't unravel during assembly. Yellow Teflon tape is thicker and rated for gas lines; use it only on gas connections. Do not use white plumbing tape on gas fittings.

You'll hear this in almost every plumbing repair that involves threaded connections — it's one of the most basic supplies to have on hand.

Thermocouple

Water Heaters Code note

A thermocouple is a small sensor that sits in the pilot flame of a standing-pilot gas heater. If the flame is present, it generates a tiny electrical signal that keeps the gas valve open. When it fails, the pilot lights and then goes out as soon as you let go of the knob. Replacing it means working at the gas control. That is a licensed plumber's repair.

You'll hear this when a pilot will not stay lit.

Gas control work belongs with a person licensed to do it, and the repair has to be tested for leaks. Do not bypass the thermocouple to keep the burner firing.

Thermostatic valve

Fixtures & Parts Code note

A shower or tub valve that maintains a precise water temperature regardless of pressure fluctuations elsewhere in the house. Unlike a pressure-balance valve (which only balances pressure), a thermostatic valve has a temperature-sensing element that adjusts the hot/cold mix to hold the set temperature. Often used in high-end shower systems and required in some care facility applications. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this when a plumber installs a premium shower system, or when discussing anti-scald protection beyond what a pressure-balance valve provides.

Threaded fitting

Pipe & Fittings

A fitting that connects to pipe via screw threads — either NPT (National Pipe Taper) threads, which taper slightly to create a tighter seal as they're tightened, or straight threads (used with a gasket or O-ring). Threaded connections are used on galvanized pipe, brass fittings, gas lines, and many valves. They require Teflon tape or pipe dope on the threads to seal properly.

You'll hear this when a plumber assembles galvanized, brass, or gas fittings, or when you're connecting a valve to a supply line.

Trap arm

Drains / Waste / Vent

The horizontal pipe that connects the P-trap to the drain pipe in the wall. It must slope slightly downward toward the wall (about 1/4 inch per foot) so water drains properly and the trap stays full. A trap arm that's too long or sloped incorrectly can cause slow drains or siphoning of the trap.

You'll hear this when a plumber adjusts the drain assembly under a sink, or when diagnosing a drain that gurgles or smells.

Trap seal

Drains / Waste / Vent Code note

The trap seal is the water that sits in a P-trap and blocks sewer gas. It is only a couple of inches deep. A rarely used floor drain loses it to evaporation. An unvented trap loses it to siphoning. When the seal is gone, you smell the sewer even though the pipe is not clogged.

You'll hear this when a bathroom smells and pouring water in the drain makes the smell stop.

The Illinois Plumbing Code sets the trap-seal depth. Vents exist to protect that seal.

Trap siphoning

Drains / Waste / Vent

Trap siphoning is the trap seal being sucked out by water moving in a poorly vented drain. You hear a gulp at the end of a drain cycle, and then you may smell sewer gas. A vent that is blocked, an S-trap, or a trap arm that is too long are the usual reasons. Pouring water back in the trap hides the smell until the next use.

You'll hear this when a sink glugs as it finishes draining and the bathroom smells afterward.

Tub shoe

Drains / Waste / Vent

The tub shoe is the fitting under a bathtub that the drain strainer screws into. It turns from the bottom of the tub into the horizontal drain. A leak here wets the ceiling below only when the tub is used, which is why it gets mistaken for a supply leak.

You'll hear this when a tub drain is being replaced from below.

U

Union

Pipe & Fittings

A three-part fitting that allows a section of pipe to be disconnected without cutting. Two threaded ends screw onto the pipes on each side, and a center nut draws them together against a gasket or ground joint. Unions are used wherever a component (like a water heater, pump, or valve) may need to be removed for service. Without a union, you'd have to cut the pipe every time.

You'll hear this when a plumber installs a water heater or pump and wants to make future service easier.

V

Vacuum breaker

Codes & Safety Code note

A vacuum breaker lets air in if the water pressure drops, so a hose or a fixture cannot siphon dirty water back into the pipes. You see small ones on hose bibbs and on some toilet fill valves. They have to be installed at the height the listing requires. A hose bibb vacuum breaker does not make it safe to leave a sprayer sitting in a bucket of chemicals.

You'll hear this when an outside faucet has a small brass cap that hisses, or a fill valve has a plastic hood.

Atmospheric vacuum breakers and similar devices are listed in the potable-water protection section of the Illinois Plumbing Code. They cannot be under continuous pressure unless the specific device is listed for it.

Valve seat

Fixtures & Parts

The valve seat is the stationary surface a washer or cartridge closes against. In an old faucet it is a replaceable brass ring down in the body. If the seat is grooved, a new washer still drips. Grinding or replacing a seat is fiddly. Doing it wrong ruins the faucet body.

You'll hear this when a new washer did not stop a drip from a two-handle faucet.

Vent stack

Drains / Waste / Vent

The vertical pipe that runs from your drain system up through the roof, allowing sewer gases to escape outside and letting air into the drain lines so water flows freely. A blocked vent stack (often from leaves or a bird nest) causes slow drains, gurgling sounds, and sewer smells inside the house.

You'll hear this when a plumber diagnoses house-wide slow drains or gurgling, or when inspecting the roof for a blocked vent.

W

Water closet

Fixtures & Parts

Water closet is the code and trade name for a toilet. The 'closet' in closet flange and closet bolt is this word, not a storage closet. On a fixture list, WC means the toilet.

You'll hear this when a drawing labels a toilet as a WC or a water closet.

Water hammer

Common Problems

The loud banging or thudding sound pipes make when water flow is stopped suddenly — like when a washing machine valve snaps shut. The pressure wave has nowhere to go and slams into the pipe. Water hammer arrestors (small shock-absorbing devices) can be installed on supply lines to fix the problem.

You'll hear this when diagnosing banging pipes, or when a plumber recommends installing arrestors on washing machine supply lines.

Water hammer arrestor

Water Supply & Quality Code note

A water hammer arrestor is a small sealed chamber, usually with a piston, installed on a supply line near a quick-closing valve. It gives the moving water somewhere to go besides into the pipe wall. Older air chambers made from a capped vertical pipe eventually fill with water and stop working.

You'll hear this when a washer bangs and someone suggests an arrestor on the laundry supplies.

Quick-closing valves are where arrestors show up in the code. A listed arrestor is not the same as a homemade air chamber.

Water heater thermostat

Water Heaters

On an electric tank, the thermostat is the control behind the access panel that tells each element when to come on. On a gas tank, the thermostat is part of the gas control knob. A normal setting is about 120°F. Turning it up to get more hot water raises the scald risk and does not fix a failed element or a tank full of sediment.

You'll hear this when someone says the heater is set too low, or a reset button on an electric thermostat has popped.

Water meter

Water Supply & Quality Code note

The water meter measures how much water enters the house. It is often in a basement, a meter pit, or at the curb. The utility owns the meter. If all the fixtures are off and the little leak indicator is still spinning, water is leaving through a leak, a running toilet, or a device you forgot. That test is one of the most useful checks in the house.

You'll hear this when someone says to watch the meter to prove there is a leak.

Do not remove or bypass a utility meter. Tampering is a utility rule, not a plumbing shortcut. The curb side of the meter is often the utility's pipe.

Water softener

Water Supply & Quality Code note

A water softener trades hardness minerals for sodium or potassium using resin beads. It regenerates by flushing a brine solution through the resin and sending that wastewater to a drain. The drain has to be air-gapped or otherwise protected. A softener that is stuck regenerating can send water to the drain all day and spin the meter.

You'll hear this when someone wants less scale, or a softener is suspected in a high water bill.

Softener discharges and the backflow protection on the water connection have to meet the Illinois Plumbing Code. Do not hard-pipe a softener drain into a sewer without the required air gap.

Wax ring

Fixtures & Parts

The wax seal between the base of a toilet and the drain flange in the floor. It creates a watertight, gas-tight connection. If a toilet rocks, leaks at the base, or you smell sewer gas near it, the wax ring may need replacing — a job that requires removing the toilet.

You'll hear this when a plumber diagnoses a leak at the base of a toilet, or when replacing a toilet.

Well pump

Water Supply & Quality Code note

A well pump lifts water from a private well and sends it to the pressure tank. It may hang in the well or sit in the basement as a jet pump. Short-cycling, air at the faucets, or no water at all are pump, tank, or water-level problems. The electrical side and the well cap are not a first DIY project.

You'll hear this when a house is not on city water and the faucets sputter.

Well construction and abandonment are regulated by state and county health rules, separate from a faucet repair. Pulling a pump or opening a well cap can violate those rules and can contaminate the well.

Wet vent

Drains / Waste / Vent Code note

A pipe that serves as both a drain and a vent for a nearby fixture at the same time. Wet venting is allowed under certain conditions in the Illinois Plumbing Code and is common in bathrooms where multiple fixtures share a single vent. Designing a wet vent system correctly requires a licensed plumber. This is general information; Illinois Plumbing Code and local amendments govern.

You'll hear this when a plumber designs the drain and vent layout for a bathroom addition or remodel.

Wye (Y-fitting)

Pipe & Fittings

A drain fitting shaped like the letter Y, with a branch that enters at a 45-degree angle. The angled branch allows flow to enter or exit more smoothly than a tee, reducing turbulence and the risk of blockages. Wyes are used in horizontal drain runs where a branch connects at an angle, and in combination with 45-degree elbows to create a cleanout access point.

You'll hear this when a plumber adds a branch to a horizontal drain line, or when installing a cleanout.